全國服務熱線
13832172293
工作原理
ZQ系列全自(zi)動(dong)(dong)自(zi)清(qing)洗過(guo)濾(lv)器(qi)(qi)(qi)(qi)是一種全自(zi)動(dong)(dong)在(zai)(zai)線自(zi)清(qing)洗水(shui)(shui)過(guo)濾(lv)器(qi)(qi)(qi)(qi),過(guo)濾(lv)器(qi)(qi)(qi)(qi)網(wang)內(nei)安裝一套(tao)不銹鋼刷,或(huo)吮(shun)吸掃描(miao)器(qi)(qi)(qi)(qi),或(huo)絲刷+吮(shun)吸組合,以上(shang)裝置(zhi)由減(jian)速(su)電(dian)機(ji)帶動(dong)(dong)旋轉,在(zai)(zai)過(guo)濾(lv)器(qi)(qi)(qi)(qi)端(duan)蓋(gai)上(shang)或(huo)底部安裝一個電(dian)動(dong)(dong)排(pai)污閥。工作時,濁水(shui)(shui)由進(jin)水(shui)(shui)口進(jin)入,通過(guo)不銹鋼楔形網(wang)過(guo)濾(lv)污物。凈水(shui)(shui)由出(chu)(chu)(chu)水(shui)(shui)口流出(chu)(chu)(chu),當(dang)污物聚集(ji)過(guo)多(duo)時,造成過(guo)濾(lv)不暢,腔體(ti)壓力上(shang)升,當(dang)進(jin)出(chu)(chu)(chu)水(shui)(shui)的壓力差值達(da)到一定值時(預(yu)先設定),壓差開關發(fa)出(chu)(chu)(chu)信(xin)號給控(kong)制器(qi)(qi)(qi)(qi),控(kong)制器(qi)(qi)(qi)(qi)啟動(dong)(dong)減(jian)速(su)機(ji)電(dian)機(ji),帶動(dong)(dong)內(nei)部裝置(zhi)旋轉刷掉或(huo)吮(shun)吸污物雜質。同時打(da)開電(dian)動(dong)(dong)排(pai)污閥,排(pai)出(chu)(chu)(chu)污物,清(qing)洗時間約為1分(fen)鐘,自(zi)清(qing)洗期間無需斷流,排(pai)污壓力損失不超(chao)過(guo)0.05MPa,流量損失不超(chao)過(guo)1%。
設備分(fen)類
按控(kong)制方式(shi),可分為手動(dong)、自(zi)動(dong)兩(liang)種類型;
按清洗方式,可分為(wei)刷(shua)式、吮吸式、刷(shua)吸式三種類型;
按(an)構造方(fang)式(shi),可(ke)分為(wei)L、Y型兩種類型。
技術參數(shu)
水(shui)溫
50℃
反沖時間(jian)
60-120秒(miao)
反沖耗水量
約500公升(sheng)(水壓4kg時)
電源
380v 、50HZ、 3相、控制(zhi)器:220v
電機功(gong)率
0.03-0.75kw
過(guo)濾器(qi)機殼
碳(tan)鋼或(huo)不銹鋼
濾網
不銹鋼(編織、燒結、楔形)
過濾精度(du)
50-3000微米
產品特點
1) 過濾(lv)精度默認為 100 微(wei)米(mi),且從 100 至 3000 微(wei)米(mi)可選,過濾(lv)面積(ji)大,納污量高, 用戶(hu)可根(gen)據實(shi)際工況定制。
2)清洗(xi)方式簡(jian)單,且清洗(xi)循環電子監控(kong)(kong),可實(shi)現(xian)自動清洗(xi)排污。全自動自清洗(xi)過濾 器控(kong)(kong)制系(xi)統中(zhong)的參(can)數可調節(jie)。
3)設有電機過載保(bao)護,可(ke)有效保(bao)護電機。
4)具有(you)在清洗排污(wu)時不間斷供水、無需(xu)旁路的特(te)點(dian),且(qie)清洗時間短(duan),排污(wu)耗水量少, 不超過總(zong)流量的 1%。
5)維修性強(qiang)、安(an)裝(zhuang)拆卸簡(jian)便易行。
6)與用(yong)戶管線的連接方(fang)式(shi)為法蘭(lan)(lan)(lan)連接,法蘭(lan)(lan)(lan)采(cai)用(yong)國標法蘭(lan)(lan)(lan),通用(yong)性(xing)強(qiang)。
式,SX刷+吮吸結合)
用戶選型(xing)參考因素:
▲系統處理水量,設備進出(chu)口通徑;
▲雜質(zhi)過濾精度要求;
▲系統工(gong)況要求,如:動力(li)源(yuan)、管道壓力(li)、空間布局、溫度;
▲過濾水(shui)體的水(shui)質(zhi)狀況;
▲對于含強(qiang)酸(suan)、強(qiang)堿或其他特殊水質等情況,應用戶要求(qiu)特殊定制;
▲過(guo)濾絮狀物,原則上不選用刷式清洗(xi),應選用吮吸式清洗(xi)設(she)計.
主要應用領域:
1、空調暖通系(xi)(xi)統(tong)(tong):有效(xiao)降(jiang)低懸浮物及(ji)濁度,解決(jue)冷凝器、冷卻器等系(xi)(xi)統(tong)(tong)堵塞問題,使除垢設備(bei)及(ji)藥劑的效(xiao)果達到佳,提高(gao)系(xi)(xi)統(tong)(tong)運行效(xiao)率;
2、鋼鐵:用于原料(liao)場(chang)、燒結球團廠水處理過濾(lv)、高爐、軋機、連鑄機等系統(tong)冷卻(que)水過濾(lv),高壓水除(chu)磷系統(tong)雜質過濾(lv);
3、汽車制造:涂(tu)裝生(sheng)產線(xian)、冷卻循(xun)環水(shui)系統,在(zai)汽車、拖拉機(ji)、摩(mo)托車、發動機(ji)制造水(shui)處理工(gong)序都(dou)有(you)廣泛應用;
4、發電(dian)(dian)廠:用于電(dian)(dian)廠鍋爐高純水制(zhi)備的精(jing)度預處理(li)部分,發電(dian)(dian)機冷卻循環水、密封用水的過濾;
5、石油化工:在(zai)循環水(shui)場做旁濾(lv)(lv)處(chu)理,可單機或多機型(xing)并(bing)聯(lian)主處(chu)理,代替濾(lv)(lv)料過濾(lv)(lv),減少(shao)濾(lv)(lv)料過濾(lv)(lv)負荷,可避免大量的沖(chong)洗耗水(shui),節約成本;
6、農業園林及造紙:在有噴(pen)頭、噴(pen)嘴系統中,應減少由于雜(za)質所造成的設(she)備(bei)堵塞、磨損,因此需要選擇(ze)高精度、高自(zi)動化(hua)過(guo)濾(lv)產品(pin);
7、給水及污水處理:用于預(yu)處理系統(tong)中(zhong),提高系統(tong)運(yun)行效率;
8、礦山:過濾(lv)井下(xia)噴淋水,保證系統工作正常;
9、機械(xie)、食品或其他:對系(xi)統進行(xing)自動、精密過濾,用來防(fang)止冷卻水系(xi)統堵塞。
控制原(yuan)理與壓(ya)差設(she)定: 軟化(hua)水
ZQ系列全自(zi)(zi)動(dong)自(zi)(zi)清洗過濾(lv)器由電機、電控(kong)(kong)箱、控(kong)(kong)制管(guan)路(包括(kuo)控(kong)(kong)制閥和(he)壓差傳感器),主管(guan)組件、濾(lv)芯(xin)組件、不銹鋼(gang)濾(lv)筒、框(kuang)架組件、傳動(dong)軸(zhou)、進(jin)出(chu)口連接法蘭等(deng)主要零部(bu)件組成,電控(kong)(kong)箱和(he)控(kong)(kong)制管(guan)路構成過濾(lv)機的控(kong)(kong)制部(bu)分,用(yong)于實(shi)現自(zi)(zi)動(dong)清洗排污過程。
ZQ系(xi)列(lie)全自動(dong)自清洗(xi)過(guo)(guo)(guo)濾器通過(guo)(guo)(guo)出水口(kou)電(dian)(dian)(dian)接點壓(ya)(ya)(ya)力(li)(li)(li)表檢測進出口(kou)壓(ya)(ya)(ya)差(cha)變化,當出水壓(ya)(ya)(ya)差(cha)達(da)到(dao)(dao)(dao)設(she)定(ding)值(zhi)時(下限值(zhi)),電(dian)(dian)(dian)控器向控制閥(fa)、電(dian)(dian)(dian)動(dong)機發(fa)送信號(hao),引發(fa)下列(lie)動(dong)作(zuo):電(dian)(dian)(dian)動(dong)機帶動(dong)轉軸旋轉,排(pai)污電(dian)(dian)(dian)磁(ci)(ci)閥(fa)打開,濾筒內部吮吸裝置(zhi)在內壓(ya)(ya)(ya)作(zuo)用下將(jiang)濾筒內壁的(de)雜(za)質吸入排(pai)污系(xi)統,通過(guo)(guo)(guo)排(pai)污電(dian)(dian)(dian)磁(ci)(ci)閥(fa)排(pai)出,從(cong)而起到(dao)(dao)(dao)對(dui)濾芯進行(xing)清洗(xi)的(de)作(zuo)用。整個(ge)清洗(xi)過(guo)(guo)(guo)程(cheng)將(jiang)持續60-90秒,當出水壓(ya)(ya)(ya)力(li)(li)(li)值(zhi)達(da)到(dao)(dao)(dao)設(she)定(ding)值(zhi)時(上(shang)限值(zhi)),排(pai)污電(dian)(dian)(dian)磁(ci)(ci)閥(fa)關閉(bi),電(dian)(dian)(dian)動(dong)機停止(zhi)轉動(dong),系(xi)統恢復(fu)至其(qi)初始狀態,為下一個(ge)過(guo)(guo)(guo)濾工(gong)序做好準備(bei)。如果第一次(ci)清洗(xi)過(guo)(guo)(guo)程(cheng)結束后,出水壓(ya)(ya)(ya)力(li)(li)(li)差(cha)仍然在下限值(zhi)上(shang),或沒有達(da)到(dao)(dao)(dao)設(she)定(ding)的(de)上(shang)限壓(ya)(ya)(ya)力(li)(li)(li)值(zhi),控制裝置(zhi)會自動(dong)重(zhong)新進行(xing)一次(ci)吮吸清洗(xi)過(guo)(guo)(guo)程(cheng),直到(dao)(dao)(dao)進出水壓(ya)(ya)(ya)力(li)(li)(li)恢復(fu)到(dao)(dao)(dao)正常值(zhi)(設(she)定(ding)的(de)上(shang)限值(zhi))。
進出水壓力設定方(fang)法:
1、設備(bei)安裝完(wan)畢(bi)后,通(tong)水試壓(ya)完(wan)成(cheng)
2、觀察進(jin)水(shui)壓力值,將出水(shui)口電(dian)接點(dian)壓力表下限值設(she)定為(wei)低于(yu)進(jin)水(shui)壓力值0.05-0.06MPa 之間,上限(xian)值(zhi)設(she)定(ding)為等于進水壓(ya)力值(zhi)或略低于進水壓(ya)力值(zhi)0.02MPa左右即可。
如:觀察(cha)進水(shui)壓(ya)力表值為0.4MPa,則將出水(shui)口電接點壓(ya)力表的(de)下(xia)限值設定為0.34-0.35 MPa之間(jian),上限值設定為0.38-0.4 MPa。